Quantcast
Channel: Integrity Servers topics
Viewing all 625 articles
Browse latest View live

How to reset iLO of specific blade in HPE-Superdome-2

$
0
0

Dear All,

I want to reset iLO of specific balde ( blade# 2) in Superdome-2 server. I have run the bellow command but shown error.

SMDC-SD2-APP04> RESET ILO 2

Invalid Arguments

RESET BLADE { <bay number> }: Reset the blade bay by momentarily removing all
power.

Here server model is CB900s i4  . Mention that OS or server can not be rebooted because live system is running here.

 

Please assist on this if anyone has exact solution

 

 


rx6600 installed and available CPU slots from command line or GIU

$
0
0

Dear HPUX Experts,

We have rx6000 server and palnning to upgrade CPU on this box. We would like to know how many CPU slots are occupied, how many free slots availabe for upgrade.

Please assist how to find this infor from command line or thro any GUI?

Thank you.

How to get HBA card location from HP-UX OS

$
0
0

Hi All,

I need help for collectiong the HBA card location from OS end. Here  system is Superdome-2 32s, OS : HP-UX 11.31

Please assist on this issue .

Enable User activity auditing in HP-UX 11.31

$
0
0

Dear Concern,

Please share me procedure to enable user activity auditing in HP-UX 11.31 system without converting the system in trusted mode and make it persistent after reboot.

Thanks.

With Best Regards,

Kauser 

 

Sudden system reboot issue

$
0
0

Dear Concern,

Our system is running on HP-UX 11.31 system. System rebooted last two days few time and from below log, we have found below entries. 

# cat /etc/shutdownlog

12:35 Thu Feb 6, 2020. Reboot: (by sdbmblv2!oracle)
12:08 Fri Feb 7, 2020. Reboot: (by sdbmblv2!oracle)  

As per my understanding, these entries mean "oracle" user reboot the system twice. My query is can "oracle" user reboot the system as it is only a normal user not superuser priviledge?

With Best Regards,

Kauser

 

OA reset for MP log clear

$
0
0

Hi All,

One blade  in  enclosure-1  is shown  Management Processor: Error . Mention that this sytem is Superdome-2 and has 2 Enclosure and  complex firmware version is 3.8.0

Now enclosure is functiong  with live production.  Here  reported blade is under nPar partition.

Already I have run on OA at online  by command : RESET iLO 2  but don't execute because firmware version is not supported.

So if we reset the blade  by command RESET BLADE 2, we must down all os and nPar but we can't do that.

So if I reset OA , it oly reset  OA ilO and blade iLO OR  reboot OS including network ??

Select -->Enclosure  -->Active Onboard Administrator -->Virtual Button  --->>>reset

 

Please need opinoin  from expert end.

http://www.supplement4advisors.com/viacen-uk/

$
0
0

Viacen UKViacen UK The present condition is actually an exceptionally focused condition where by a great many people has a cozy day by day plan and because of this dynamic method for living people as a rule overlook their wellbeing. Be that as it may, should you be in the midst of individuals who comply with adjusted and solid eating regimen and do practice much of the time and miss the mark to achieve this strong weight lifter style constitution then its a particular follow the eating regimen plan you hold fast to isn't generally adequate for it and you is inadequate in some basic sustenance.

http://www.supplement4advisors.com/viacen-uk/

Integrity server problem, shuts down

$
0
0

The Integrity rx2660 system has just shutdown on its own twice in the past week.  There is some problem with it.  The System Health and Internal Health LEDs were flashing amber or red.  The logs show:

BMC        *5   0x2057442171020090 FFFF0307D0020300  VOLTAGE_DEGRADES_TO_NON_RECOVERABLE

BMC        *7   0x20574421710200A0 D000A870D01120300  SHUTDOWN_OR_RESET_ON_SENSOR

Any ideas on what the issue could be?  If the power supply or CPU or motherboard need to be replaced?  Or if something can just be fixed without the need to replace components. 

Thanks

 

 

 


Nano installed OK but there is an endless list of screen messages

$
0
0

We are trying to install nano on HP-UX 11.31 from the orting centre. It is a brand new Itanium server. After resolving the dependancies and missing libraries it appears to run but has a string of messages sent to the terminal where we are trying to run it. They look like the following

"Cannot remove alias 'kterm terminal emulator which supports graphics'
Name collision 'kterm terminal emulator which supports graphics' between
and kterm terminal emulator which supports graphics
Cannot remove alias 'kterm terminal emulator which supports graphics'
Name collision 'kterm terminal emulator which supports graphics' between
and kterm terminal emulator which supports graphics
Cannot remove alias 'kterm terminal emulator which supports graphics'
Name collision 'FM series MS-DOS V3.1 (TERM)' between
FM series MS-DOS V3.1 (TERM)
and FM series MS-DOS V3.1 (TERM)"

This prevents us from using it. Any ideas?

 

http://amazon4expert.org/immunity-oil-reviews/

$
0
0

Immunity Oil>>Buy the #1 Best-Selling Immunity Oil 2020 >>  These sortCBD Oils of things can't deal with the important drivers of the problem. In like manner, they might reason some real blue reactions. It is in each case better to select honestly the general and confided in matters, as an example, . … Read More:->> http://amazon4expert.org/immunity-oil-reviews/

wbem

$
0
0

Hi,

I just notice an error in my syslog and I'm unable to find why, any help would be appreciated.

May 26 13:56:25  cimservera[29650]: [Authentication failed] Password not valid
May 26 13:56:27  cimservera[29725]: [Authentication failed] Password not valid
May 26 13:56:27  cimservera[29729]: [Authentication failed] Password not valid
May 26 13:56:27  cimservera[29736]: [Authentication failed] Password not valid
May 26 13:56:30 cimservera[29921]: [Authentication failed] Password not valid

This message is coming every 5 minutes.

Thanks,

Installing new Motherboard on RX2660 integrity server

$
0
0

Hi, 

one of our HP RX2660 server went down with system not booting, even no display, and SEL showed fatal error, as shown is last,

The problem isolated to motherboard (by testing the CPU in other system and it worked fine), We ordered new motherboard and need to install, But I don't have any experience before, so can anyone guide me the procedure? if any settings need to be backup from old board or the new board will work itself?

Log Entry 176: 27 Nov 2019 07:55:06

Alert Level 7: Fatal

Keyword: BOOT_NOT_DETECTED

No events were received from system firmware

Logged by: Baseboard Management Controller;

Sensor: Processor

Data1: FRB2/Hang in POST failure

0x205DDE2BDA020C90 FFFF036F00070300

 

DMP_TO_AMP_COMM_LOST

$
0
0

I have found the new err log in ilo of BL890

Keyword: DMP_TO_AMP_COMM_LOST
the ilo peer to peer lan communication between dmp and amp was lost
Data: ASCII message - DMP5AMP8
A98020E040E10056 38504D4135504D44

Who can tell me what does this mean? 

Super dome event

$
0
0

Alert level 2: Informational
Keyword: CACHE_CHECK_INFO
It indicates a cache error occurred and data field contains check info data.
Reporting Entity: System Firmware located in cabinet 0, slot 4, cpu 1
Problem Detail: 0x1880019b00240910
0x4e801c9f41e00ed0 0x1880019b00240910
0x4b001c9f41e00ed1 0x01000000575004cc

IR volume disque missing

$
0
0

ir volume  : primary ok  secondary  missing  apres echange du disque  idem   

ioscan : un disque (autre path) en supplement

Raid Level : RAID 1
Volume sas address : 0x5605d6c74ffa0d2
Device Special File : /dev/rdsk/c5t4d0
Raid State : DEGRADED
Raid Status Flag : ENABLED
Raid Size : 139236
Rebuild Rate : 0.00 %
Rebuild Progress : 100.00 %

Participating Physical Drive(s) :

SAS Address Enc Bay Size(MB) Type State

0x5000c500838e0205 1 1 286102 PRIMARY ONLINE
0x0 0 0 286102 SECONDARY MISSING

 


Rx8640 stuck at the MP login prompt

$
0
0

 I have a RX-8640 stuck at the MP Login prompt. How do I get back to the console?  Other than resetting the power? I don't know the MP password, nor does Control-B work.

 

 

How to go from MP menu to EFI shell

$
0
0

This is on rx-8640 Itanium. I am booted into MP menu. What next step do I take to get into EFI?

How to reset console on a rx8640?

$
0
0

The console keeps writing junk to the screen, with every line that is displayed or typed.  You can still see the text you type but it's surrounded by junk.

 

Unable to select FS0: to boot off the CD

$
0
0

I cannot boot off the CD, when I do map -r I get just one LUN device. I cannot select any FSx: at all. 

reconnect -r shows 11 devices

 

MP Console not responding

$
0
0

Has anyone seen this behavior before, or can anyone offer advice.

I had a problem with this server (bl860c blade in c7000 enclosure, using Virtual Connect).     The server has been running without a problem for ~4 years, however I suspect a problem with the LOM ports on the blade.    Basically I couldn’t connect to it via the network, it was not responding to a ping, and when I logged into the iLo to get to the console I can get no response from the Console Screen.    What I got was this;

   MP MAIN MENU:

         CO: Console

        VFP: Virtual Front Panel

         CM: Command Menu

      SMCLP: Server Management Command Line Protocol

         CL: Console Log

         SL: Show Event Logs

         HE: Main Help Menu

          X: Exit Connection

 

[mp0019bbc50862] MP> CO 

        [Use Ctrl-B or ESC-( to return to MP main menu.]

- - - - - - - - - - Prior Console Output - - - - - - - - - -

- - - - - - - - - - - - Live Console - - - - - - - - - - - -

At this point, I am unable to get any response on the live console.     I tried cycling the power on the server, which should have at least displayed the initialization information, ending at the BOOT Manager Screen, but I got no output at all.   

The Onboard Administrator indicates no issues with the server, i.e Power On, System Health OK, and Status OK.    The System Event Log on MP shows nothing unusual.    

From the Command Menu I have tried;

“RB”   Reset BMC

“RS”   Reset system through RST signal.

“TC”   Reset system via “INIT”

“XD”  Reset MP

And I have cycled power several times.     None of these actions gave any response at the Live Console screen.      The only action (I can think of) that I haven’t tried is to move the blade to another bay.

I am reaching the conclusion that even though the enclosure software (OA and VC) are all indicating that the Blade is OK, I am beginning to doubt this.    

I would appreciate any assistance/suggestions that you can offer.

Dave Baxter
 

Viewing all 625 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>