Hello,
I have a systems which had a power supply unit failure, and after replace of the PSU unit the systems fails to boot with the messages shown here below:
Log Entry 83: 07 May 2019 07:23:21
Alert Level 7: Fatal
Keyword: BOOT_HALT_CELL
Cell or system halt
Logged by: System Firmware 0
Data: Major change in system state
0xF480003700E00170 000000000000000F
Log Entry 81: 07 May 2019 07:23:21
Alert Level 7: Fatal
Keyword: MEM_NO_MEM_FOUND
No memory found
Logged by: System Firmware 0
Data: Data field unused
0xE08000D100E00140 0000000000000000
# Location|Alert| Encoded Field | Data Field | Keyword / Timestamp
-------------------------------------------------------------------------------
16 SFW 0 *7 0xF480003700E00170 000000000000000F BOOT_HALT_CELL
07 May 2019 07:23:21
14 SFW 0 *7 0xE08000D100E00140 0000000000000000 MEM_NO_MEM_FOUND
07 May 2019 07:23:21
SYSREV
Current firmware revisions
MP FW : F.02.17
BMC FW : 05.23
EFI FW : ROM A 07.12, ROM B 07.12
System FW : ROM A 04.03, ROM B 04.03, Boot ROM A
PDH FW : 50.07
DHPC FW : 01.23
UCIO FW : 03.0b
PRS FW : 00.08 UpSeqRev: 0c, DownSeqRev: 08
HFC FW : 00.04 SetRev: 00
Thanks for you kind help to restore the said machine.